WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development.

WISE-7504M is a multi-function module with 4-channel analog inputs, 4-channel analog outputs and 4-channel digital inputs. It provides various programmable analog inputs, and analog outputs. Each analog input is allowed to configure a proper range with 240 Vrms high voltage protection. WISE-7504M follows IEEE 802.3af-compliant Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs. In additional to this, WISE-7504M also has a built-in two-port thernet switch to implement daisy-chain topology. The cabling is much easier and total costs of cable and switch are significantly reduced.

By integrating with IF-THEN-ELSE rule engine, WISE-7504M provides more powerful functions such as I/O Moniitoring/Control, Counter, Timer, Schedule, E-mail sending & CGI Command sending for use in various industrial applications. WISE-7504M also supports Modbus TCP and MQTT protocol to make seamless integration with SCADA, IT and IoT (Internet of Things) system.

Features

  • Runs on browsers, no extra software tool is required.

  • No more programming, Web pages provided for control logic editing.

  • IF-THEN-ELSE logic rules execution ability.

  • Built-in I/O (AI: 4 Channels; AO: 4 Channels; DI: 4 Channels)

  • Support I/O Moniitoring/Control, Counter, Timer, Schedule, Email sending and CGI Command sending operations.

  • Modbus TCP Protocol for SCADA System Integration.

  • IEEE 802.3af-compliant Power over Ethernet (PoE).

  • 2-port Ethernet Switch for Daisy-Chain Topology.

  • MQTT Protocol for IT & IoT (Internet of Things) System Integration.

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.

Hardware Specifications

Analog Input

Channels

4 (Differential)

Type

±500 mV, ±1 V, ±5 V, ±10 V,
+0 mA to +20 mA, ±20 mA, 4 to 20 mA (Jumper Selectable)

Resolution

16-bit

Sampling Rate

10 Samples/Second (Total)

Accuracy

±0.1 %

Zero Drift

±20 μV/°C

Span Drift

±25 ppm/°C

Overvoltage Protection

240 Vrms

Overcurrent Protection

50 mA Max. at 110 VDC/VAC Max.

Common Voltage Protection

±200 VDC

Overcurrent Protection

Yes, 50 mA at 110 VDC

Virtual Channel to Channel Isolation

Yes, 400 VDC

Open Wire Detection for 4 ~ 20 mA

Yes

Input Impedance

Voltage

2 MΩ

Current

125 Ω

Common Mode Rejection

86 dB Min.

Normal Mode Rejection

100 dB

Analog Output

Channels

4

Type

+0 VDC to +5 VDC, ±5 VDC, +0 VDC to +10 VDC,±10 VDC,
+0 mA to +20 mA, +4 mA to +20 mA (Jumper Selectable)

Resolution

12-bit

Accuracy

±0.1% of FSR

Voltage Output Capability

20 mA @ 10 V

Current Load Resistance

400 Ω

Open Wire Detection

Yes, for 4 to 20 mA only

Digital Input/Counter

Channels

4

Dry Contact
(Source)

On Voltage Level

Close to GND

Off Voltage Level

Open

Effective Distance for Dry Contact

500 M Max.

Wet contact
(Sink/Source)

On Voltage Level

+1 VDC Max.

Off Voltage Level

+3.5 VDC to +30 VDC

Counters

Max. Counts

16-bit (65535)

Max. Input Frequency

50 Hz

Min. Pulse Width

10 ms

Overvoltage Protection

30 VDC

Communication

Ethernet Port

2 x RJ-45, 10/100 Base-TX, Swtich Ports

PoE

Yes

Protocol

Modbus TCP, MQTT

LED Indicators

for System Running

Yes

for Ethernet Link/Act

Yes

for I/O Channel Status

Yes

for PoE Power

Yes

2-Way Isolation

I/O

2500 VDC

EMS Protection

ESD (IEC 61000-4-2)

±4 kV Contact for Each Terminal and 
±8 kV Air for Random Point

EFT (IEC 61000-4-4)

±2 kV for Power Line

Surge (IEC 61000-4-5)

±2 kV for Power Line

Power

Reverse Polarity Protection

Yes

Powered from Terminal Block

12 to 48 VDC

Powered from PoE

Yes, IEEE 802.3af, Class1

Consumption

5.1 W (Max.)

Mechanical

Dimensions (L x W x H)

120mm x 97mm x 42mm

Installation

Wall mounting

Environment

Operating Temperature

-25 °C to +75 °C

Storage Temperature

-30 °C to +80 °C

Humidity

10 to 90% RH, non-condensing

Software Specifications

Functions

Rule Configuration Website

Access Web server on WISE controllers to edit and upload logic rules through web browser.

72 IF-THEN-ELSE Logic Rules

3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions

48 Internal Registers

Hold temporary variables and read/write data

24 Timers

Delay / Timing functions.

24 Schedules

Setup prescheduled routine tasks.

24 Emails

Send Email messages to pre-set Email receivers.

24 CGI Commands

Send pre-set CGI commands.

24 Recipes

Set up THEN/ELSE action groups.

8 P2P remote modules

Set up the connection information for the remote WISE modules.

Modbus TCP Protocol

Real time control and monitoring I/O channels and system status of controllers via SCADA software.

MQTT Protocol

Real time message publish/subscribe mechanism for I/O channels and system status via IT/IoT software.

IF Conditions

DI Channel

ON, OFF, ON to OFF, OFF to ON, Change

AI Channel

= 、> 、< 、 ≥ 、 ≤ (value)

Internal Register

DI Counter

= 、> 、< 、 ≥ 、 ≤ (value), Change

Timer

Timeout, Not Timeout

Schedule

In Range, Out of Range

P2P

DI, AI, DI counter, DO counter, IR

Rule Status

Enable, Disable

THEN / ELSE Actions

AO Channel

Change the value

Internal Register

DI Counter

Reset

Timer

Start, Reset

Schedule

Enable, Disable

Email

Send

MQTT message

CGI Commands

Recipe

Execute

P2P

DO(On/Off), AO, IR

Rule Status

Enable, Disable

Download

Manual

Software

Data sheet

Certification

Odering information

WISE-7504M CR WISE IoT I/O Module with 4-channels AI, 4-channels AO, 4-channels DI and 2-port Ethernet Switch(RoHS)

Accessories

  • GPSU06U-6 : 24 V/0.25 A, 6 W Power Supply

  • MDR-20-24 : 24 V/1 A, 24 W Power Supply with DIN-Rail Mounting

  • NS-205 CR : Unmanaged 5-Port Industrial Ethernet Switch (RoHS)

  • NS-205PSE CR : Unmanaged 5-Port Industrial PoE Ethernet Switch (RoHS)

Sản phẩm đã được thêm vào giỏ hàng

Số lượng:

Tổng tiền:

Sản phẩm đã được thêm vào giỏ hàng

Phí vận chuyển: Tính khi thanh toán

Tổng tiền thanh toán: