Bộ lập trình nhúng IoT Wise ICP DAS WISE-7115

Thương hiệu: ICP DAS | Tình trạng: Còn hàng
Liên hệ

WISE-7115 CR 7-channel RTD Input with 3-wire RTD lead resistance elimination PoE Module (RoHS)

Gọi +84 904251826 để được trợ giúp

Bộ lập trình nhúng IoT Wise ICP DAS WISE-7115

WISE-7115: 7-channel RTD Input with 3-wire RTD lead resistance elimination PoE Module

Introduction

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.

WISE-7115 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7115 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.

This module WISE-7115 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 16-bit, 7-channel RTD inputs. Each channel is allowed to configure an individual range that supports 3-wire RTD lead resistance elimination and open wire detection for RTD measurement.

Features

  • Built-in Web Server for IF-THEN-ELSE rule setting

  • Built-in IF-THEN-ELSE rule enigne for logic operation

  • No more programming. Just click and get done!

  • Support IO, Counter, Timer, Email operations

  • Modbus/TCP Protocol for SCADA Software Seamless Integration

  • IEEE 802.3af-compliant Power over Ethernet (PoE)

  • 10/100 Base-TX Ethernet

  • AI Type: 7 RTD (Pt100, Pt1000, Ni120, Cu100, Cu1000)

  • Individual Channel Configuration

  • 3-wire RTD Input with Lead Resistance Elimination

  • 2-way Isolation/ESD Protection

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.

Hardware Specifications

Analog Input

Input Channels

7 (Differential)

Sensor Type

Pt100, Pt1000, Ni120, Cu100, Cu1000

Wire Connection

2/3 wire

Resolution

16-bit

Sampling Rate

12 Samples/Sec. (Total)

Accuracy

±0.05%

Zero Drift

±0.5 μV/°C

Span Drift

±20 μV/°C

Common Mode Rejection

150 dB

Normal Mode Rejection

100 dB

Input Impedance

>1M Ω

Open Wire Detection

Yes

Individual Channel Configurable

Yes

3-wire RTD Lead Resistance Elimination

Yes

System

CPU

16-bit CPU

SRAM

512 KB

Flash Memory

512 KB

EEPROM

16 KB

Watchdog

Yes

Communication

PoE Ethernet Port

10/100 Base-TX and automatic MDI/MDI-X

2 Way Isolation

I/O

2500 VDC

EMS Protection

ESD (IEC 61000-4-2)

±4 kV Contact for each terminal and ±8 kV Air for random point

EFT (IEC 61000-4-4)

±4 kV for Power Line

LED Indicators

PoE

PoE On

L1

System Running

L2

Ethernet Link/Act

L3

Ethernet 10/100M Speed

Power Requirements

Reserve Polarity Protection

Yes

Powered from terminal block

Yes, 12 ~ 48 VDC

Powered from PoE

Yes, IEEE 802.3af, Class1

Consumption

2.6 W

Mechanical

Dimensions (W x H x D)

72 mm x 123 mm x 35 mm

Installation

DIN-Rail or Wall mounting

Environment

Operating Temperature

-25 °C ~ +75 °C

Storage Temperature

-30 °C ~ +80 °C

Humidity

10 ~ 90% RH, non-condensing

Software Specifications

Functions

Rule Configuration Website

Access Web server on WISE controllers to edit and upload logic rules through web browser.

36 IF-THEN-ELSE Logic Rules

3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions

48 Internal Registers

Hold temporary variables and read/write data via Modbus/TCP address.

12 Timers

Delay / Timing functions.

12 Emails

Send Email messages to pre-set Email receivers.

12 CGI Commands

Send pre-set CGI commands.

12 Recipes

Set up THEN/ELSE action groups.

8 P2P remote modules

Set up the connection information for the remote WISE modules.

Modbus/TCP Protocol

Real time control and monitoring I/O channels and system status of controllers via SCADA software.

IF Conditions

AI Channel

= 、> 、< 、 ≥ 、 ≤ (value)

Internal Register

Timer

Timeout、Not Timeout

P2P

DI、AI、DI counter、DO counter、IR

Rule Status

Enable、Disable

THEN / ELSE Actions

Internal Register

Change the value

Timer

Start、Stop

Email

Send

CGI Commands

Recipe

Execute

P2P

DO(On/Off)、AO、IR

Rule Status

Enable、Disable

Download

Manual

Software

Data sheet

Certification

Odering information

WISE-7115 CR 7-channel RTD Input with 3-wire RTD lead resistance elimination PoE Module (RoHS)

Accessories

  • GPSU06U-6 : 24 V/0.25 A, 6 W Power Supply

  • MDR-20-24 : 24 V/1 A, 24 W Power Supply with DIN-Rail Mounting

  • NS-205 CR : Unmanaged 5-Port Industrial Ethernet Switch

  • NS-205PSE CR : Unmanaged 5-Port Industrial PoE Ethernet Switch (RoHS)

Sản phẩm đã được thêm vào giỏ hàng

Số lượng:

Tổng tiền:

Sản phẩm đã được thêm vào giỏ hàng

Phí vận chuyển: Tính khi thanh toán

Tổng tiền thanh toán: