Bộ lập trình nhúng IoT Wise và lưu trữ Datalogger ICP DAS WISE-5800-MTCP

Thương hiệu: ICP DAS | Tình trạng: Còn hàng
Liên hệ

WISE-5800-MTCP CR User-defined I/O & Data Logger Module for Modbus TCP Devices

Gọi 0904251826 để được trợ giúp

Bộ lập trình nhúng IoT Wise và lưu trữ Datalogger ICP DAS WISE-5800-MTCP

WISE-5800-MTCP: User-defined I/O & Data Logger Module for Modbus TCP Devices

Introduction

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development.

WISE-5800-MTCP supports an I/O expansion bus to implement various I/O functions such as D/I, D/O, A/D and D/A according to the XW-Board. In addition, WISE-5800-MTCP also supports Modbus TCP slave devices. Based on the connection ability with Modbus TCP slave devices, WISE-5800-MTCP can provide user more flexibility in application field.

WISE-5800-MTCP supports Modbus TCP/RTU protocol to make seamless integration with SCADA software available. It includes all advantages which WISE series controllers can provide. In addition, WISE-5800-MTCP provides data logger function with microSD card, it can record I/O channel value by event trigger or regular time period. The data files can be sent back by Email or FTP. All setting can be completed through browser.

Features

  • Built-in Web Server for IF-THEN-ELSE rule setting

  • Built-in IF-THEN-ELSE rule enigne for logic operation

  • No more programming. Just click and get done!

  • Support IO, Counter, Timer, Schedule, Email, Recipe operations

  • Data logger and data files send back function supported

  • Modbus TCP/RTU Protocol for SCADA Software Seamless

  • Support XW-Board

  • Support Modbus TCP Slave Devices(Up to 7)

  • SNTP Time Synchronization Supported

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc

Hardware Specifications

CPU Module

CPU

16-bit CPU

SRAM

768 KB

Flash

512 KB

EEPROM

16 KB

NVRAM

31 Bytes

microSD Expansion

Support up to 32 GB microSDHC card

RTC (Real Time Clock)

Provide second, minute, hour, date of week, month and year

Watchdog

Yes

Communication Ports

Ethernet

RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X)

COM 1

RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max.

COM 2

RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed: 115200 bps max. (Reserved)

LED Indicators

System LED

Yes (Red)

Ethernet Link LED

Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received)

Hardware Expansion

I/O Expansion Bus

Yes

Power Requirements

Protection

Power Reverse Polarity Protection

Frame Ground

Yes (for ESD Protection)

Input Range

12 ~ 48 VDC

Redundant Power Input

Yes

Power Consumption

2.0 W

Mechanical

Dimensions (W x H x D)

91 mm x 123 mm x 52 mm

Installation

DIN-Rail

Environment

Operating Temperature

-25 ~ +75 °C

Storage Temperature

-30 ~ +80 °C

Ambient Relative Humidity

10 ~ 90% RH (non-condensing)

Software Specifications

 

Functions

Rule Configuration Website

Access Web server on WISE controllers to edit and upload logic rules through web browser.

36 IF-THEN-ELSE Logic Rules

3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions

48 Internal Registers

Hold temporary variables and read/write data via Modbus/TCP address.

12 Timers

Delay / Timing functions.

12 Schedules

Setup prescheduled routine tasks.

12 Emails

Send Email messages to pre-set Email receivers.

12 CGI Commands

Send pre-set CGI commands.

12 Recipes

Set up THEN/ELSE action groups.

Data Logger

Set up the Data Logger configuration, include the data record format, and data file sending operation.

Modbus TCP/RTU Protocol

Real time control and monitoring I/O channels and system status of controllers via SCADA software.

IF Conditions

DI Channel

ON、OFF、ON to OFF、OFF to ON、Change

AI Channel

= 、> 、< 、 ≥ 、 ≤ (value)

Internal Register

DI Counter

= 、> 、< 、 ≥ 、 ≤ (value)、Change

Timer

Timeout、Not Timeout

Schedule

In Range、Out of Range

Rule Status

Enable、Disable

THEN / ELSE Actions

DO Channel

ON、OFF、Pulse Output ( apply to XW-Board only)

AO Channel

Change the value

Internal Register

DI Counter

Reset

Timer

Start、Reset

Schedule

Enable、Disable

Email

Send

CGI Commands

Recipe

Execute

Data Logger

Start、Stop、One-Time Log

Rule Status

Enable、Disable

Support I/O Module List

I/O Type

Functions

Modules

XW-Board

DI/DO

XW107, XW110

DI/DO/AI/AO

XW304, XW310, XW310C

Modbus TCP Slave Module

Coil Output / Discrete Input / Input Register / Holding Register

Download

Manual

Software

Data sheet

Certification

Odering information

WISE-5800-MTCP CR User-defined I/O & Data Logger Module for Modbus TCP Devices

Accessories

  • GPSU06U-6 : 24 V/0.25 A, 6 W Power Supply

  • MDR-20-24 : 24 V/1 A, 24 W Power Supply with DIN-Rail Mounting

  • NS-205 CR : Unmanaged 5-Port Industrial Ethernet Switch (RoHS)

  • NS-205PSE CR : Unmanaged 5-Port Industrial PoE Ethernet Switch (RoHS)

Sản phẩm đã được thêm vào giỏ hàng

Số lượng:

Tổng tiền:

Sản phẩm đã được thêm vào giỏ hàng

Phí vận chuyển: Tính khi thanh toán

Tổng tiền thanh toán: