Module truyền thông 1 cổng CANopen Master ICP DAS I-87123

Thương hiệu: ICP DAS | Tình trạng: Còn hàng
Liên hệ

I-87123-G One port intelligent CANopen master interface module.

Gọi 0904251826 để được trợ giúp

Module truyền thông 1 cổng CANopen Master ICP DAS I-87123

Introduction

CANopen, a kind of communication protocols, is based on the intelligent field bus(CAN bus). It was developed as a standardized embedded network with highly flexible configuration capabilities. It provides standardized communication objects for real-time data(Process Data Objects, PDO), configuration data(Service Data Objects, SDO), network management data(NMT message, and Error Control), and special functions(Time Stamp, Sync message, and Emergency message). Nowadays, CANopen is used in many various application fields, such as medical equipment, off-road vehicles, maritime electronics, public transportation, building automation and etc. I-87123 main control unit is specially designed for the master device of CANopen protocol. It supplies many features for users, such as dynamic PDO, EMCY object, error output value, SYNC object, …and etc.

Application

  • Industrial Machinery

  • Laboratory Equipment & Research

  • Restaurant Appliances

  • Maritime

  • Medical

  • Specialty Vehicles...etc

Features

  • One CANopen master communication port

  • Standard CANopen specification DS-301 v4.02

  • Support node id 1 ~ 127

  • Programmable bauds:10 K, 20 K, 50 K, 125 K, 250 K, 500 K, 800 K, and 1M bps

  • Scan function for scanning all nodes on the same CANopen network

  • Provide master listen mode for monitoring without bothering the CANopen network

  • Support both Node Guarding Protocol and Heartbeat Consumer Protocol

  • Provide event trigger function for EMCY event, Node Guarding event and Heartbeat event

  • Provide Event-triggered, remote-requested, cyclic and acyclic SYNC of PDO mode

  • The PDO communication supports single byte output so that users can just modify the value of one byte without changing the others

  • Allow dynamic PDO mapping

  • Allow to get multi PDOs data simultaneously

  • The SDO communication supports segment protocol

  • Programmable master node ID for the CANopen slave function

  • Support the EDS file

  • Provide pre-configure the slave node, and connect it automatically while booting up

  • CPMUtility utility tool for testing users' CANopen network

  • Support ViewPAC-2000, WinPAC-8000, XPAC-8000 and XPAC-8000-CE6

  • Provide VC++,VB.Net, and C# demos and function libraries

  • Support InduSoft Driver

  • 256 records CANopen message receive buffer size

  • 2500 Vrms poto-isolation protection on CAN side

  • 3 indication LEDs (PWR, Rx/Tx and ERR LEDs)

Software

The CPMUtility utility can easily to access the I/O data of all the slave devices. The users can monitor the input data of the specific slave device and change the output data to the remote slave device with this utility.

  • Auto-scan all the CANopen master devices that the CPMUtility has supported

  • Auto-scan all the CANopen slave devices on the CANopen network

  • Support the EDS file

  • Dynamic PDO object setting easily

  • Guarding Event and Heartbeat Event detection

  • EMCY message receiving

  • Maximum 5 SYNC message producers per CANopen master

Hardware

Hardware

CPU

80186, 80 MHz or compatible

SRAM/Flash/EEPROM

512 KB / 512 KB / 2 KB

CAN Interface

Controller

NXP SJA1000T with 16 MHz clock

Transceiver

NXP 82C250

Channel number

1

Connector

5-pin screw terminal block (CAN_GND, CAN_L, CAN_SHLD, CAN_H, N/A)

Baud Rate (bps)

10 k, 20 k, 50 k, 125 k, 250 k, 500 k, 800 k, 1 M

Transmission Distance (m)

Depend on baud rate (for example, max. 1000 m at 50 kbps )

Isolation

3000 VDC for DC-to-DC, 2500 Vrms for photo-couple

Terminator Resistor

Jumper for 120 Ω terminator resistor

Specification

ISO 11898-2, CAN 2.0A and CAN 2.0B

Protocol

CANopen DS-301 ver4.02

Bus Interface

Type

Serial I/O module

LED

Round LED

PWR LED, RUN LED, ERR LED

Software

Supported Platform

ViewPAC-2000, WinPAC-8000, XPAC-8000, XPAC-8000-CE6 (ISaGRAF not supported)

SDK

eVC++4.0, VC++ 6.0, VC++ 2005, VB.Net 2005, C#.Net 2005

Power

Power Consumption

2 W

Mechanism

Dimensions

31mm x 115mm x 91mm (W x L x H)

Environment

Operating Temp.

-25 ~ 75 ℃

Storage Temp.

-30 ~ 80 ℃

Humidity

10 ~ 90% RH, non-condensing

Download

Pin

Driver

Firmware