Bộ chuyển đổi Modbus RTU/ASCII sang HART ICP DAS HRT-310

Thương hiệu: ICP DAS | Tình trạng: Còn hàng
Liên hệ

HRT-310 CR Modbus RTU/ASCII to HART Gateway (Upright) (RoHS)

Gọi 0904251826 để được trợ giúp

Bộ chuyển đổi Modbus RTU/ASCII sang HART ICP DAS HRT-310

The HRT-710 / HRT-310 Gateway is specially designed for the master device of HART protocol. It allows the Modbus master to access the HART devices. These HART devices may be a transmitter, an actuator and so forth. In addition, we also provide the software utility, HG_Tool, for module configuration and HART device diagnosis. By using these modules, users can integrate their HART devices into Modbus network easily and quickly.

Application

  • Industrial Automation

  • Factory Automation

  • Process Automation

  • Etc…

HRT-710 / HRT-310, a HART master to Modbus slave gateway, is applied to integrate the information from these HART flow meters into the customer's HMI system. Through the HRT-710 / HRT-310, all of the HART flow meters will be regarded as Modbus slave devices and the HMI system can use the built-in Modbus RTU communication to access these HART flow meters easily.

More than 250 HART device information needs to be integrated to surveillance center. In PC side, uses 3 pieces of PCI cards (VXC-148U, for 24 channels RS-485 expansion). I-2542A and I-2542B (RS-485 to Fiber) are used in every RS-485 channel to extend RS-485 communication distance. There are about 20 pieces of HRT-710 modules used in every RS-485 channel with the different station ID. Through the structure, SCADA or HMI system can integrate all HART device information via Modbus protocol easily and quickly.

Features

  • Support HART Short/Long frame

  • Support HART Burst mode

  • Allow two HART Masters

  • Working in point-to-point or multi-drop HART mode

  • Connecting up to 15 HART modules

  • Support Modbus RTU and ASCII format

  • Support Modbus Slave mode

  • Support firmware update via Com Port. (FW_v1.2 and HW_v1.2)

  • Support on-line replacement of HART devices. (FW_v1.5)

  • Support acquire Long Frame Address automatically (FW_v1.5)

  • Isolated COM Port : RS-232/422/485

  • Provide LED indicators

  • Built-in Watchdog

  • DIN Rail or Wall Mounting

HRT-710

HRT-310

Din Rail Installation

Horizontal

Upright

HART Signal

Standard

Enhanced send/receive signal 
(For long distance comm.)

Loop Power

No

Support
(module provides +30V output)

Built-In Resistor

250 Ohm (1/4W)

250 Ohm (1W)

Ulitily

  • Provide the system and communication configuration of HRT-710 / HRT-310

  • Provide the Modbus address table for HART command data

  • Provide the diagnostic information of HRT-710 / HRT-310 module and HART device

  • Provide send / receive HART command to access HART device

  • Provide "Load/Save" module configuration file to apply to other HRT-710 / HRT-310 quickly

Modbus Support

Support the following Modbus commands

Code

Name

Description

01

Read Coil Status

Read the ON/OFF status of discrete outputs in the slave

02

Read Input Status

Read the ON/OFF status of discrete inputs in the slave

03

Read Holding Registers

Read the binary contents of holding registers in the slave

04

Read Input Registers

Read the binary contents of input registers in the slave

05

Force Single Coil

Write a single output to either ON or OFF in the slave

06

Preset Single Register

Write an integer value into a single register in the slave

15

Force Multi. Coils

Write each coil in the sequence of coils to either ON or OFF in the slave

16

Preset Multi. Registers

Write a block of contiguous registers in the slave

Hardware Specification

Model Name

HRT-710

HRT-310

UART Interface

COM Port

RS-232(3 wires) / RS-422 / RS-485

Baud Rate (bps)

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

Protocol

Modbus RTU / Modbus ASCII

Connector

9-pin screwed terminal block

 4-pin screwed terminal block

HART Interface

HART Channel

1

HART Interface

2-pin screwed terminal block

HART Device

2-wired or 4-wired HART devices

HART Topology

Point to Point or Multi-Drop

HART Data

Only Digital Data

HART Frame Type

Short and Long Frame

Burst Mode

Supported

Max. HART Device

15

Isolation

UL1577 Spec.

Loop Resistor

250 Ω (1/4W) by Jumper

250 Ω (1W) by Dip-Switch

Loop Power

No

Yes (module provides +30V output) 

Power

Power supply

Unregulated +10 ~ +30 VDC

Protection

Power reverse polarity protection, Over-voltage brown-out protection

Power Consumption

1 W

 3.5W (Max.)

Mechanism

Installation

DIN-Rail or Wall Mounting (Horizontal)

DIN-Rail (Upright)

Dimensions

72 mm x 35 mm x 121 mm (W x L x H) Detail

25 mm x 116 mm x 120 mm (W x L x H)

Environment

Operating Temp.

-25 ℃ ~ +75 ℃

Storage Temp.

-30 ℃ ~ +80 ℃

Humidity

5% ~ 95% RH, non-condensing

Download

Pin

Software

Firmware

Manual

Data sheet

Odering information

HRT-710 CR

Modbus RTU/ASCII to HART Gateway (RoHS)

HRT-310 CR

Modbus RTU/ASCII to HART Gateway (Upright) (RoHS)

Sản phẩm đã được thêm vào giỏ hàng

Số lượng:

Tổng tiền:

Sản phẩm đã được thêm vào giỏ hàng

Phí vận chuyển: Tính khi thanh toán

Tổng tiền thanh toán: