GW-7238D CR: Bộ chuyển đổi Gateway J1939 sang Modbus TCP Server / RTU Slave

Thương hiệu: ICP DAS | Tình trạng: Còn hàng
Liên hệ

GW-7238D CR J1939 to Modbus TCP Server / RTU Slave Gateway included CA-0910 cable(RoHS)

Gọi +84 904251826 để được trợ giúp

GW-7238D CR: Bộ chuyển đổi Gateway J1939 sang Modbus TCP Server / RTU Slave

Features

Module specs

• RoHS Design
• Provide PWR / ERR / J1939 / MODBUS indication LEDs
• The built-in jumper to select 120 ohm terminal resistor of CAN bus
• Watchdog inside

J1939 Features

• Transmission and reception of all types of J1939 messages, including PDU1, PDU2, broadcast and destination specific
• J1939 Transport Protocol for transmission and reception of large messages (9 - 1785 bytes)
• Supported BAM of Connection Management Message
• Network addresses management

Modbus Features

• Support RS-232, RS-485 and Ethernet interfaces
• Support Modbus TCP server / RTU slave protocol
• Communication support both Modbus TCP / RTU to J1939 at the same time
• Configurable UART baud rates of 9600, 19200, 38400, 57600, 115200 bps
• Allow Max 5 Modbus TCP clients to access GW-7238D simultaneously
• Support Function Code 03 / 04 / 06 / 16 of Modbus functions for reading and writing J1939 Messages

Introduction

The GW-7238D is a gateway that provides conversion between J1939 and Modbus TCP/RTU protocol. For J1939 network, the GW-7238D supports PDU1, PDU2, broadcast and destination specific type of J1939 messages. For Modbus TCP/RTU network, the GW-7238D is a Modbus TCP server / RTU slave to reply the request from Modbus TCP client / RTU master. Utility software is provided for users to configure J1939 and Modbus TCP/RTU setting in the GW-7238D. The application fields can be diesel power-train applications, In-Vehicle networks for trucks and buses, etc.
The following figure shows the application architecture for the GW-7238D

Applications

• Diesel power-train applications
• Diesel power-train applications
• In-Vehicle networks for trucks and buses
• Truck-Trailer connections
• On Board Diagnostics
• Vehicle Automation

Specifications

CPU Module
CPU 80186, 80 MHz or compatible

 

LED Indicators
Status PWR / J1939 / MODBUS / ERR

 

COM Ports
Ports 1 x RS-232
1 x RS-485 (Self-turner inside)
Baud Rate 9600, 19200, 38400, 57600, 115200
Protocol Modbus RTU

 

Ethernet
Protocol RJ-45 with LED indicator / Modbus TCP

 

J1939
Controller NXP SJA1000T with 16 MHz clock
Transceiver NXP 82C250
Ports 1
Baud Rate 250 k
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Terminal Resistor Jumper for 120 Ω terminal resistor
Specification ISO-11898-2, CAN 2.0A and CAN 2.0B

 

Power
Consumption 2 W

 

Mechanical
Dimensions (mm) 122 x 72 x 33 (L x W x H)
Installation DIN-Rail

 

Environmental
Operating Temperature -25 ~ +75 ℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing