Bộ chuyển đổi Gateway J1939 sang Modbus TCP Server / RTU Slave ICP DAS GW-7238D

Thương hiệu: ICP DAS | Tình trạng: Còn hàng
Liên hệ

GW-7238D CR J1939 to Modbus TCP Server / RTU Slave Gateway included CA-0910 cable(RoHS)

Gọi 0904251826 để được trợ giúp

Bộ chuyển đổi Gateway J1939 sang Modbus TCP Server / RTU Slave ICP DAS GW-7238D

The GW-7238D is a gateway that provides conversion between J1939 and Modbus TCP/RTU protocol. For J1939 network, the GW-7238D supports PDU1, PDU2, broadcast and destination specific type of J1939 messages. For Modbus TCP/RTU network, the GW-7238D is a Modbus TCP server / RTU slave to reply the request from Modbus TCP client / RTU master. Utility software is provided for users to configure J1939 and Modbus TCP/RTU setting in the GW-7238D. The application fields can be diesel power-train applications, In-Vehicle networks for trucks and buses, etc.

The following figure shows the application architecture for the GW-7238D

Applications

 

  • Diesel power-train applications

  • Diesel power-train applications

  • In-Vehicle networks for trucks and buses

  • Truck-Trailer connections

  • On Board Diagnostics

Features

Module specs

  • RoHS Design

  • Provide PWR / ERR / J1939 / MODBUS indication LEDs

  • The built-in jumper to select 120 ohm terminal resister of CAN bus

  • Watchdog inside

J1939 Features

  • Transmission and reception of all types of J1939 messages, including PDU1, PDU2, broadcast and destination specific

  • J1939 Transport Protocol for transmission and reception of large messages (9 - 1785 bytes)

  • Supported BAM of Connection Management Message

  • Network addresses management

Modbus Features

  • Support RS-232, RS-485 and Ethernet interfaces

  • Support Modbus TCP server / RTU slave protocol

  • Communication support both Modbus TCP / RTU to J1939 at the same time

  • Configurable UART baud rates of 9600, 19200, 38400, 57600, 115200 bps

  • Allow Max 5 Modbus TCP clients to access GW-7238D simultaneously

  • Support Function Code 03 / 04 / 06 / 16 of Modbus functions for reading and writing J1939 Messages

Hardware Specifications

Hardware

CPU

80186, 80 MHz or compatible

CAN Interface

Controller / Transceiver

NXP SJA1000T with 16 MHz clock / NXP 82C250

Channel number

1

Connector

5-pin screwed terminal block (CAN_L, CAN_H, N/A for others)

Baud Rate (bps)

250 k

Isolation

1000 VDC for DC-to-DC, 2500 Vrms for photo-couple

Terminator Resistor

Jumper for 120 Ω terminator resistor

Specification / Protocol

ISO-11898-2, CAN 2.0A and CAN 2.0B / J1939

UART Interface

COM 1 / Protocol

RS-232 / Modbus RTU

COM 1 Connector

5-pin screwed terminal block (TxD, RxD, RTS, CTS, GND)

COM 2 / Protocol

RS-485 (Self-turner inside) / Modbus RTU

COM 2 Connector

2-pin screwed terminal block (DATA+, DATA-)

Ethernet Interface

Controller

10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX)

Connector / Protocol

RJ-45 with LED indicator / Modbus TCP

LED

Round LED

PWR / J1939 / MODBUS / ERR

Power

Power supply

Unregulated +10 ~ +30 VDC

Protection

Power reverse polarity protection, Over-voltage brown-out protection

Power Consumption

2 W

Mechanism

Installation

DIN-Rail

Dimensions

122mm x 72mm x 33mm (L x W x H)

Environment

Operating Temp.

-25 ~ 75 ℃

Storage Temp.

-30 ~ 80 ℃

Humidity

10 ~ 90% RH, non-condensing

Download

Pin

Wire

Manual

Data sheet

Software

FAQ

Certification

Odering information

GW-7238D CR

J1939 to Modbus TCP Server / RTU Slave Gateway included CA-0910 cable(RoHS)

Sản phẩm đã được thêm vào giỏ hàng

Số lượng:

Tổng tiền:

Sản phẩm đã được thêm vào giỏ hàng

Phí vận chuyển: Tính khi thanh toán

Tổng tiền thanh toán: