EC150 CO2/H2O Open-Path Gas Analyzer

 

Gọi 0904251826 để được trợ giúp

Thiết bị phân tích khí GAS CO2/H20 Campbell Scientific EC150

Overview

Campbell Scientific’s EC150 is an open-path analyzer specifically designed for eddy-covariance flux measurements. As a stand-alone analyzer, it simultaneously measures absolute carbon-dioxide and water-vapor densities, air temperature, and barometric pressure. With the optional CSAT3A sonic anemometer head, the EC150 also measures three-dimensional wind speed and sonic air temperature.

Benefits and Features

  • Unique optical configuration gives a slim aerodynamic shape with minimal wind distortion

  • Analyzer and sonic anemometer measurements are synchronized by a common set of electronics

  • Maximum output rate of 60 Hz with 20 Hz bandwidth

  • Low power consumption; suitable for solar power applications

  • Low noise

  • Measurements are temperature compensated without active heat control

  • Angled windows to shed water and are tolerant to window contamination

  • Field rugged

  • Field serviceable

  • Factory calibrated over wide range of CO2, H2O, pressure and temperature in all combinations encountered in practice

  • Extensive set of diagnostic parameters

  • Fully compatible with Campbell Scientific dataloggers; field setup, configuration, and field zero and span can be accomplished directly from the datalogger

  • Speed of Sound: Determined from three acoustic paths; corrected for crosswind effects

  • Rain: innovative signal processing and transducer wicks considerably improve performance of the anemometer during precipitation events

Detailed Description

The CSAT3A has the following outputs:

  • Ux (m/s)*

  • Uy (m/s)*

  • Uz (m/s)*

  • Sonic Temperature (°C)*

  • Sonic Diagnostic*

The EC150 has the following outputs:

  • CO2 Density (mg/m3)

  • H2O Density (g/m3)

  • Gas Analyzer Diagnostic

  • Ambient Temperature (°C)

  • Atmospheric Pressure (kPa)

  • CO2 Signal Strength

  • H2O Signal Strength

  • Source Temperature (°C)

*The first five outputs require the CSAT3A Sonic Anemometer Head.

 

Specifications

Operating Temperature Range

-30° to +50°C

Calibrated Pressure Range

70 to 106 kPa

Input Voltage

10 to 16 Vdc

Power

5 W (steady state and power up) at 25⁰C

Measurement Rate

60 Hz

Output Bandwidth

5, 10, 12.5, or 20 Hz (user-programmable)

Output Options

SDM, RS-485, USB, analog (CO2 and H2O only)

Auxiliary Inputs

Air temperature and pressure

Gas Analyzer/Sonic Volume Separation

5.0 cm (2.0 in.)

Warranty

3 years or 17,500 hours of operation (whichever comes first)

Cable Length

3 m (10 ft) from EC150 and CSAT3A to EC100

Weight

  • 2.0 kg (4.4 lb) for EC150 head and cables

  • 1.7 kg (3.7 lb) for CSAT3A head and cables

  • 3.2 kg (7.1 lb) for EC100 electronics

Gas Analyzer

Path Length

15.37 cm (6.05 in.) 
A temperature of 20°C and pressure of 101.325 kPa was used to convert mass density to concentration.

Gas Analyzer - CO2 Performance

-NOTE-

A temperature of 20°C and pressure of 101.325 kPa was used to convert mass density to concentration.

Accuracy

  • Assumes the following: the gas analyzer was properly zero and spanned using the appropriate standards; CO2 span concentration was 400 ppm; H2O span dewpoint was at 12°C (16.7 ppt); zero/span temperature was 25°C; zero/span pressure was 84 kPa; subsequent measurements made at or near the span concentration; temperature is not more than ±6°C from the zero/span temperature; and ambient temperature is within the gas analyzer operating temperature range.

  • 1% (standard deviation of calibration residuals)

Precision RMS (maximum)

0.2 mg/m3 (0.15 µmol/mol) 

Nominal conditions for precision verification test: 25°C, 86 kPa, 400 μmol/mol CO2, 12°C dewpoint, and 20 Hz bandwidth.

Calibrated Range

0 to 1,000 μmol/mol (0 to 3,000 µmol/mole available upon request.)

Zero Drift with Temperature (maximum)

±0.55 mg/m3/°C (±0.3 μmol/mol/°C)

Gain Drift with Temperature (maximum)

±0.1% of reading/°C

Cross Sensitivity (maximum)

±1.1 x 10-4 mol CO2 /mol H2O

Gas Analyzer - H2O Performance

-NOTE-

A temperature of 20°C and pressure of 101.325 kPa was used to convert mass density to concentration.

Accuracy

  • Assumes the following: the gas analyzer was properly zero and spanned using the appropriate standards; CO2 span concentration was 400 ppm; H2O span dewpoint was at 12°C (16.7 ppt); zero/span temperature was 25°C; zero/span pressure was 84 kPa; subsequent measurements made at or near the span concentration; temperature is not more than ±6°C from the zero/span temperature; and ambient temperature is within the gas analyzer operating temperature range.

  • 2% (standard deviation of calibration residuals)

Precision RMS (maximum)

0.004 g/m3 mmol/mol (0.006 mmol/mol) 

Nominal conditions for precision verification test: 25°C, 86 kPa, 400 μmol/mol CO2, 12°C dewpoint, and 20 Hz bandwidth.

Calibrated Range

0 to 72 mmol/mol (38°C dewpoint)

Zero Drift with Temperature (maximum)

±0.037 g/m3/°C (±0.05 mmol/mol/°C)

Gain Drift with Temperature (maximum)

±0.3% of reading/°C

Cross Sensitivity (maximum)

±0.1 mol H2O/mol CO2

Sonic Anemometer - Accuracy

Offset Error

  • < ±8.0 cm s-1 (for ux, uy)

  • < ±4.0 cm s-1 (for uz)

  • ±0.7° while horizontal wind at 1 m s-1 (for wind direction)

Gain Error

  • < ±2% of reading (for wind vector within ±5° of horizontal)

  • < ±3% of reading (for wind vector within ±10° of horizontal)

  • < ±6% of reading (for wind vector within ±20° of horizontal)

Measurement Precision RMS

  • 1 mm s-1 (for ux, uy)

  • 0.5 mm s-1 (for uz)

  • 0.025°C (for sonic temperature)

  • 0.6° (for wind direction)

Speed of Sound

Determined from 3 acoustic paths (corrected for crosswind effects)

Rain

Innovative ultrasonic signal processing and user-installable wicks considerably improve the performance of the anemometer under all rain events.

Ambient Temperature

Manufacturer

BetaTherm 100K6A1IA

Total Accuracy

±0.15°C (-30°C to +50°C)

 

Download

Brochures

EC150 CO2 and H2O Open-Path Gas Analyzer with Optional 3D Sonic Anemometer

Manuals

EC150 CO2 and H2O Open-Path Gas Analyzer and EC100 Electronics with Optional CSAT3A 3D Sonic Anemometer

Open Path Eddy Covariance System with IRGASON or EC150/CSAT3A Quick Deploy Guide

EC150-GH Packing Information

EC150-SH Packing Information

Technical Papers

EC150, IRGASON, or EC155: Which CO2 and H2O Eddy-Covariance System Is Best for My Application?

EdiRe Software for Micrometeorological Applications

Miscellaneous

Using Molecular Sieve to Zero Infrared Gas Analyzers for Eddy Covariance or Atmospheric Profile Measurements

Sản phẩm đã được thêm vào giỏ hàng

Số lượng:

Tổng tiền:

Sản phẩm đã được thêm vào giỏ hàng

Phí vận chuyển: Tính khi thanh toán

Tổng tiền thanh toán: