Bộ thu thập và lưu trữ dữ liệu Campbell Scientific Datalogger CR200X

Thương hiệu: Campbell Scientific | Tình trạng: Còn hàng
Liên hệ

CR200X Datalogger

Gọi 0904251826 để được trợ giúp

Bộ thu thập và lưu trữ dữ liệu Campbell Scientific Datalogger CR200X

Overview

The CR200X, our smallest lowest-cost datalogger, provides stand-alone operation in harsh, remote environments. It reads input from one or two sensors, then transmits the data using communication peripherals. CRBasic, its full programming language, supports simple or complex programming. Multiple CR200Xs can be configured as a network, or units can be deployed individually.

Benefits and Features

  • Ideal applications include wind energy, rural water, water level/flow, aquaculture, water quality

  • Campbell Scientific’s smallest, lowest cost datalogger

  • Gas Discharge Tube (GDT) protected inputs

  • Optimal for measuring one or two simple sensors

  • Makes SDI-12, single-ended analog, pulse, switch closure, and bridge measurements

  • Battery-backed clock that ensures accurate time is maintained while datalogger is disconnected from battery power

  • Program with LoggerNet, PC400, or Short Cut to fit your setup

  • PakBus, Modbus, and SDI-12 protocols supported

Detailed Description

The CR200X has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.

The CR200X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples (refer to the Compatibility information for compatible sensors, peripherals, and software). Recalibration services are not offered for the CR200X datalogger.

Specifications

-NOTE-

Note: Additional specifications are listed in the CR200X-Series Specifications Sheet.

Maximum Scan Rate

1 Hz

Analog Channels

  • The single-ended analog inputs can also be used as control ports.

  • 5 single-ended (no differential) individually configured

Pulse Count Channels

2

Switched Excitation Channels

2 voltage

Digital Ports

  • Certain digital ports can be used to count switch closures.

  • 2 I/O

Communication Ports

1 RS-232

Switched Battery Port

1

Input Voltage Range

0 to 2500 mV

Analog Voltage Accuracy

±(0.25% of reading + (1.2 mV)x(offset)) at -40° to +50°C

Analog Voltage Resolution

0.6 mV

A/D Bits

12

Operating Temperature

-40° to +50°C

Power Requirements

7 to 16 Vdc

Typical Current Drain

  • ~0.2 mA (quiescent)

  • ~3 mA (active)

Clock Accuracy

  • 8.2 min./month (@ -40° to +50°C)

  • 1 min./month (@ +25°C)

Protocols Supported

PakBus (leaf node only), SDI-12

CE Compliance Standards to which Conformity Is Declared

IEC61326:2002

Warranty

3 years

Dimensions

14.0 x 7.6 x 4.8 cm (5.5 x 3.0 x 1.9 in.)

Weight

242 g (8.5 oz)

Memory

Final Storage

512 kB of flash memory for approximately 125,000 data points

Operating System

106 kB of flash memory

Intermediate Storage

8 kB of SRAM for communication buffers, calculations, variables, etc.

Download

Brochures

CR200X-Series Dataloggers / Wireless Sensors

CR200X-Series Specifications

Manuals

CR200/CR200X-series Dataloggers

PakBus Networking Guide

Sản phẩm đã được thêm vào giỏ hàng

Số lượng:

Tổng tiền:

Sản phẩm đã được thêm vào giỏ hàng

Phí vận chuyển: Tính khi thanh toán

Tổng tiền thanh toán: